This is published simultaneously in Emcrit
Emergency Medicine News has now published 2 “Myth-Busting” articles by Rory Spiegel which dispute the value of high-sensitivity troponin. We call them “Fake News,” (as they cherry-pick and misrepresent several studies) and EM News would not allow rebuttal.
Emergency Medicine News has now published 2 “Myth-Busting” articles by Rory Spiegel which dispute the value of high-sensitivity troponin. We call them “Fake News,” (as they cherry-pick and misrepresent several studies) and EM News would not allow rebuttal.
The bottom line: the value of high-sensitivity troponin
is NOT a myth; it helps to rule out and rule in acute MI earlier (but it is
complex, and there is a lot to know).
Stephen W. Smith*
Alexander Limkakeng**
Frank Peacock***
Disclosures:
*Dr. Smith has researched the Abbottt
Architect high-sensitivity assay with the Hennepin Healthcare Research
Institute’s Biomarkers Research Lab, which has received funding from
Abbottt. He has no personal disclosures.
**Dr.
Limkakeng:
Has
done research into high-sensitivity troponin funded by Roche, Abbott, and Siemens.
***Dr.
Peacock’s disclosures:
--Research
Grants: Abbott, Boehringer Ingelheim, Braincheck, CSL Behring, Daiichi-Sankyo,
Immunarray, Janssen, Ortho Clinical Diagnostics, Portola, Relypsa, Roche,
Salix, Siemens. --Consultant: Abbott, Astra-Zeneca, Bayer, Beckman,
Boehrhinger-Ingelheim, Ischemia Care, Dx, Immunarray, Instrument Labs, Janssen,
Nabriva, Ortho Clinical Diagnostics, Relypsa, Roche, Quidel, Salix, Siemens.
--Expert
Testimony: Johnson and Johnson.
--Stock/Ownership
Interests: AseptiScope Inc, Brainbox
Inc, Comprehensive Research Associates LLC, Emergencies in Medicine LLC,
Ischemia DX LLC.
This piece is in response to an
article in Emergency Medicine News, in the series "Myths in Emergency
Medicine":
Myths in Emergency Medicine: Hoopla
Aside, hs-cTnI is Not Catching Missed MIs.
Spiegel, Rory,
MD
Dr.
Spiegel was responding to this very complicated article in Lancet:
We
wrote our rebuttal, and then Dr. Spiegel doubled down this month by publishing another “Myths in EM”
piece in EM News: “Is hs-cTnT Worth the Downstream Testing?.
Rebuttal to the First Article
Stephen
Smith, of Dr. Smith’s ECG blog, wrote this rebuttal: Smith SW. Letter to the Editor: hs-cTnI’s True
Intent. Emergency Medicine News;
41(5):28-49; May 2019. https://journals.lww.com/em-news/Fulltext/2019/05000/Letter_to_the_Editor__hs_cTnI_s_True_Intent.39.aspx
Alex
Limkakeng and Frank Peacock also responded:
Here is the Smith response:
Note
that units in contemporary assays are reported in ng/mL, and in
high-sensitivity (hs) assays as ng/L (cTnI of 0.030 ng/mL is comparable to hs
cTnI of 30 ng/L)
To
The Editor:
I believe Rory Spiegel,
MD, misinterpreted the study in his article, “Hoopla Aside, hs-cTnI is Not Catching
Missed MIs.” (EMN 2019;41[2]:1; http://bit.ly/2Bv4FUd.)
The high-sensitivity troponin (in this case, Abbott Architect hs troponin I)
reclassified 1771 patients as acute MI (about 600 type 1) not identified by the
(Abbott) contemporary assay (cTnI), and their ultimate outcome was not
different from those not reclassified. (Lancet
2018;392[10151]:919; http://bit.ly/2Erob73.)
This makes it seem that
the hs assay has no value, that it simply leads to more investigations without
improving outcomes. The reason for this is not increased test sensitivity but
the threshold used for the test's upper reference limit (URL). It also ignores
the intended value of the test: earlier MI rule in or out.
The definitions of
normal vs. increased for both assays are based on the 99th percentile
of a normal population, which may result in varying cutpoints for normal. The
upper reference limit must also be accompanied by a low coefficient of
variation (CV), which statistically measures the reproducibility of the test
and should not exceed 10% at the 99th percentile. Different labs
have different CVs and URLs; the laboratories used in the study had a 10% CV at
a relatively high URL of 40 and 50 ng/L, higher than it would be in many labs.
The URL for the same (Abbott Architect) contemporary cTnI assay in the Hennepin
County lab is 0.030 ng/mL, and the CV is less than 10% at this value. The
higher URL would result in the cTnI assay being less sensitive in the study
than it would otherwise. The hs assay uses different thresholds for women (16 ng/L)
and men (34 ng/L). This is likely why women were reclassified in the study more
often.
These factors may
account for the differences in reclassification. Data from the UTROPIA study,
in which the URL for cTnI was 0.030 ng/mL (hs-cTnI used 16 ng/L for women, 34
for men), showed fewer positive assays with the hs-cTnI than with the cTnI;
that is, it resulted in fewer false-positives. (Am J Med 2017;130[12]:1431.)
It is also important to
remember that “high-sensitivity” means analytical, not clinical, sensitivity.
All positives and negatives are determined arbitrarily by the 99th
percentile of a “normal population” without ACS symptoms; thus, as long as the
2 “normal” populations on which the 2 assays’ normal values were defined are
comparable, the two assays cannot be different in the proportion of MIs
identified except for the different thresholds used and the number of hours of
serial troponins measured.
I like to call
high-sensitivity assays “high-precision” assays because they can accurately
quantify low levels of troponin, far below the 99th percentile
cutpoint. This means that troponin changes at low levels can be detected in
order to rule in or rule out MI earlier by using low thresholds or delta
values. Small changes at low values are true changes, not just analytical
noise. A single extremely low value, which can now be quantified, can all but
rule out MI in patients with at least two hours of chest pain. (JAMA 2017;318[19]:1913; http://bit.ly/2MVSsMT.)
The Lancet study used values at six to 12
hours after symptom onset to diagnose myocardial injury. The contemporary (not
high-sensitivity, hs) assay (cTnI) is excellent and just as sensitive as hs
assays at six to 12 hours after symptom onset. The use of these late
measurements negated the value of the hs assay, which is that it helps in early
diagnosis of MI and early rule out. It is true that the hs assays will not catch
missed MIs, but that was never the intent.
Stephen
W. Smith, MD. Minneapolis, MN
Here is the response of Drs.
Limkakeng and Peacock:
To the Editor:
The
headline and publication reviewed in the EMN
article, “Hoopla Aside, hs-cTnI is Not Catching Missed MIs” are misleading.
(2019;41[2]:1; http://bit.ly/2Bv4FUd.)
Rory Spiegel, MD, wrote, “Despite our hopes, it would appear that the
introduction of hs-cTnI added very little to the workup of patients presenting
with symptoms concerning for ACS.” On the contrary, a wide body of published
research demonstrates that hs troponin can positively affect ED evaluation of
ACS if properly implemented.
Our
European and Asian colleagues have shown us for years that the value of a
high-sensitivity troponin assay is not to identify more MIs but to identify
patients who can be safely discharged home faster. Indeed, the literature is
rife with examples of how this can be done. (Circulation 2017;135[16]:e923; http://bit.ly/2tzs02Q;
Eur Heart J 2016;37[44]:3324; http://bit.ly/2NjMFAO.)
Our
early experience at Duke University Hospital has confirmed this experience
(manuscript in preparation). Thoughtful high-sensitivity troponin
implementation strategies that incorporate structured risk stratification and
disposition pathways significantly reduce length of ED stays, admission and
stress testing rates, and costs without a concomitant increase in hard
cardiovascular outcomes such as MI and death in those discharged. Note that
these outcomes cannot be achieved simply by changing your troponin assay. They
require an evidence-based, multidisciplinary change in the practice of ACS
evaluation.
We
agree that it is unfortunate that these assays have been termed
high-sensitivity because their real value is high precision and
reproducibility. This allows for accurate serial measurements in a short time.
They also allow more precise identification of extremely low (undetectable)
levels that can allow safe discharge after one lab draw in select patients who
present several hours after symptom onset.
Alexander T. Limkakeng
Jr., MD
Durham, NC
W. Frank Peacock, MD
Houston
Dr.
Spiegel responded to all of us:
Thanks
to Drs. Smith and Limkakeng and Peacock for their insightful comments. Both are
well versed in their understanding of the literature surrounding the use of
high-sensitivity troponins, and both argue that the results of Shah, et al.,
discussed in my EMN article are
discordant from the remaining literature which demonstrates that
high-sensitivity troponin assays can be used to safely discharge patients home
from the ED without increasing the number of patients identified as positive
for an acute myocardial infarction. They go on to cite a number of studies to
support these claims.
While
a number of studies have demonstrated that the introduction of a
high-sensitivity assay allowed clinicians to send more patients home from the
ED without increasing the number of patients diagnosed with AMI, an equal
number have demonstrated the opposite. (Acad
Emerg Med 2017;24[3]:388; http://bit.ly/2Nuefvl;
Heart 2014;100[20]:1591; Emerg Med J 2012;29[10]:805; Acad Emerg Med 2014;21[7]:727; http://bit.ly/2IzUcg5.)
Multiple studies have found that the use of high-sensitivity troponin is at
best no better than the standard assay or at worst increases downstream
testing.
In
fact, all the studies that support the use of a high-sensitivity troponin are
observational in nature. Their results are promising, but they are highly
vulnerable to bias because of their observational design. The only other RCT I
am aware of comparing the use of standard to high-sensitivity troponin assay
found the high-sensitivity assay offered no clinical value over and above the
standard assay. (Circ Cardiovasc Qual
Outcomes 2016;9[5]:542; http://bit.ly/2U7kHuR.)
The results presented by Shah, et al., are even more concerning. They suggest
not only that the assay is not beneficial, but also that it may lead to more
downstream care with no recognizable benefit.
Both
Drs. Smith and Limkakeng offer logical reasons why the Shah results do not
represent the true value of a high-sensitivity assay, and they may be correct.
Shah's results may be due to how the assay was deployed rather than the assay
itself. But it is just as likely that the results are a representation of what
will occur when high-sensitivity assays are introduced into the clinical arena.
These results should not be written off because they are discordant from a
sampling of observational data supporting the use of high-sensitivity assays.
Rather, it is our responsibility to empirically demonstrate the clinical value
of the high-sensitivity assay before welcoming its widespread use in EDs across
the country.
Drs. Smith, Limkakeng,
and Peacock responded with the following, but EM News would not print it.
So here it is:
Real
Myth-Busting for high-sensitivity Troponin
Recently,
in Emergency Medicine News, Rory
Spiegel wrote in his "Myth Busting" column about the HighSTEACS study
(1) and claimed that “the introduction of hs-cTnI added very little to the
workup of patients presenting with symptoms concerning for ACS”.
This position could not be more
wrong.
We
countered his piece with reference to the mountains of data which contradict
the idea that hs troponin adds little. He responded by stating "While a number of studies
have demonstrated that the introduction of a high-sensitivity assay allowed
clinicians to send more patients home from the ED without increasing the number
of patients diagnosed with AMI, an equal number have demonstrated the
opposite."
In fact, the 4 articles he references do not show
the opposite at all, and the 5th study, and RCT, was also mischaracterized.
These are addressed point-by-point below.
His
response ignores a decade of research detailing how high-sensitivity assays can
beneficially impact ED patients. There are many systematic reviews,
meta-analyses, and prospective randomized trials from dozens of countries and
tens of thousands of patients on use of high-sensitivity troponin for safe
rapid ED discharge (just for example, Zhelev Z,et al. BMJ. 2015 Jan 20;350:h15. Than MP, et al. Circ 2018; 137 (4):
354-63, Twerenbold R, et al. Eur Heart J. 2016 Nov 21;37(44):3324-3332) The
literature is replete with data showing how proper
implementation of high-sensitivity troponin can avoid increased workups and
downstream testing, while at the same time decreasing ED length of stay and costs.
The
HighSTEACS article referenced had several flaws. Most importantly, the
advantage of hs troponin is its precision, which allows it to quantify very low
levels of troponin, and accurately measure very small changes. Thus, it is used for early rule-in or rule out
of MI. Measurements at 6-12 hours, as
done in the HighSTEACS trial, would not be expected to result in improvements
over the contemporary assay; at this time period, contrary to conventional
thinking, hs troponins are neither more sensitive nor less specific. Moreover, the finding of an increase in
workups without improvement in outcomes was due to a “positive” cutoff, defined
as the assay’s 99th percentile.
The 99th percentile may be used to rule out MI, but not rule
it in. This common error has been recognized for years. See the “10 Commandments of Troponins”
(Jaffe, AS. Heart 2011 97: 940-946 doi: 10.1136/hrt.2009.185751). This should
be considered a well-established standard for improving the clinical utility of
biomarker.
It
is important to remember that the most important use of hs troponin is the early
rule out and rule-in of MI (early rule-in by very high levels or large
deltas). Protocols for both rule out and
rule-in always have an intermediate range of values for which it is necessary
to use delta troponin and other clinical data in order to make the diagnosis.
In
fact, there are hundreds of articles that show the utility of hs troponins, and
below we describe the 4 articles which he purports show the
"opposite."
- (Acad
Emerg Med 2017;24[3]:388; http://bit.ly/2Nuefvl; This paper actually shows that a single hs troponin (measured at
time of arrival in the ED) which is below the level of detection,
especially with a normal EKG, has a 99.1% sensitivity for acute MI. It supports our argument fully; it does
not show the "opposite."
Notice how all the other studies (the 3
below) cited by Dr. Spiegel are from 5 or more years prior (even 2012!), most
of them gathering data from before 2010 (2007, 2008) when hs assays were not
very sensitive or precise.
- Heart 2014;100[20]:1591; https://heart.bmj.com/content/100/20/1591 (data from
2008-2010).
This study is downright dangerous. The cutoff used for the contemporary assay
(0.200 ng/mL) was far higher than the 99th %-ile (0.070 ng/mL). Many patients should have been diagnosed with
MI (by the contemporary assay) who were not.
In other words, the researchers used the diagnostic cutoff for the
high-sensitivity assay, but a much higher cutoff (thus not sensitive) cutoff
for the contemporary assay. This would
obviously lead to more "positives" for the high-sensitivity
assay. The authors set the cutoff for
the contemporary assay such that many patients who actually were having an
acute MI (by definition) were not diagnosed with MI. Their
conclusion might be that, because the 6 month MACE is the same in both groups,
one need not diagnose every myocardial infarction.
But with a study this small and with only
a 6 month followup, and results which contradict all other studies on acute MI,
it no doubt underestimates the adverse events.
All other data would show that missed MI, even with troponin values at
less than 5x the upper reference limit, does lead to adverse events. See JAMA reference below by Mills Nicholas L
et al.,*** in which 39% of patients with
MI whose troponin levels were between 0.05 and 0.19 ng/mL had death or MI
within one year, vs. 7% of those with troponin less than 0.05 ng/mL. Indeed, elevated troponin in the lower range
from any cause is associated with worse outcomes. Thus,
this study should be ignored.
Furthermore, the high-sensitivity assay is a previous generation hs-cTnT
which is not as precise as the one produced today, and so has more false
positives.
- Emerg Med J 2012;29[10]:805; Could not get
full text. This very old study does
not compare the "hs" troponin with any other strategy. In fact, it showed fairly good sensitivity
at 2 hours. This article does not
show the "opposite."
- Acad Emerg Med 2014;21[7]:727; http://bit.ly/2IzUcg5.) This study had a total of
24 myocardial infarctions. No more
need be said.
***Mills study, referenced above,
showing that minimally elevated contemporary troponins are associated with much
worse outcomes in MI:
Mills, Nicholas L., Antonia M. D. Churchhouse, Kuan Ken Lee, Atul Anand,
David Gamble, Anoop S. V. Shah, Elspeth Paterson, et al. 2011. “Implementation
of a Sensitive Troponin I Assay and Risk of Recurrent Myocardial Infarction and
Death in Patients with Suspected Acute Coronary Syndrome.” JAMA: The Journal of the American Medical Association 305 (12):
1210–16. https://doi.org/10.1001/jama.2011.338.
Spiegel: “The only other RCT I am aware of
comparing the use of standard to high-sensitivity troponin assay found the
high-sensitivity assay offered no clinical value over and above the standard
assay. (Circ Cardiovasc Qual Outcomes
2016;9[5]:542; http://bit.ly/2U7kHuR.) “
- Circ Cardiovasc Qual Outcomes 2016;9[5]:542; used 99%ile dichotomously “normal: less than or equal to 14 ng/L and greater
than 14 ng/L: myocardial injury]”
However,
again, among patients classified as low or no risk by Heart Foundation
Criteria, a higher rate of discharge from
the ED was observed in the hs-report group (hs-report: 168 of 253 patients
(66.4%) versus std-report: 148 of 263 patients (56.3%); P=0.010),
“There
was no difference in angiography (hs-report: 11.9% versus std-report: 10.9%; P=0.479). . . . However, among those with troponin levels less
than 30 ng/L, a modest reduction in the primary end point was observed
(hs-report: 2.6% versus std-report: 4.4%, [hazard ratio, 0.58; 95% confidence
interval, 0.34–0.1.00; P=0.050).
High-sensitivity
troponin reporting alone is associated with only modest changes in practice.
Clinical effectiveness in the adoption of high-sensitivity troponin may require
close coupling with protocols that guide interpretation and care.”
In other words, there was clinical
value:
10% increase in discharges and 2% decrease in 1 year death or recurrent ACS in
the subset expected to be stratified best by the hs trop, both statistically
significant.
Finally, there is now a very large
prospective trial that was presented at the European Society of Cardiology in
August 2019. It is the HiSTORIC trial
and is by the very same HIGH-STEACS group who published the Lancet study that
generated all this controversy.
_______________
Mills NL et al. high-sensitivity
cardiac Troponin at presentation tO Rule out myocardial InfarCtion (HiSTORIC):
a stepped-wedge cluster randomized controlled trial.
New Protocol:
Abbott
Architect hs-cTnI
Exclude
patients with STEMI and clearly ischemic ECG
--If
presentation value less than 5 ng/L and time to presentation greater than 2
hours, then low risk.
--If
less than 2 hours, or hs-cTnI greater than or equal to 5 ng/L, then obtain 3
hour troponin. If delta greater than or equal to 3, then admit for peak test.
--If
presentation value greater than 99th percentile gender specific value, admit
for peak test.
Compared to standard Evaluation:
--Hs
Troponin less than 99th percentile at presentation if greater than 6 hours of
symptoms, or
--Serial
testing 6-12 hours from symptoms onset
(This
protocol is no different from using contemporary troponin because at this late
time period, as cTnI and hs-cTnI are not significantly different).
Outcomes:
--30-day
death or MI
--Proportion
discharged from ED
--Secondary
safety endpoint: 1 year MI, cardiac death, unplanned revascularization,
re-attendance
31,492
patients overall: standard pathway - 14,700; Early rule out 16,792
Results:
Reduced
length of stay by 3.3 hours (10.1 vs. 6.8 hours)
Increased
discharge from ED by 57%
One
year MI and cardiac death higher in the standard group.
Conclusion: Early rule out protocol is
effective and safe.
We
refer interested readers to the following excellent reviews of high-sensitivity
troponin implementation:
Response to the 2nd “Myth-busting”
article
Interestingly,
on Nov 5, Dr. Spiegel published another “Myths in EM”
piece in EM News: “Is hs-cTnT Worth the Downstream Testing?.
The piece assesses a new randomized trial of the Roche hs -cTnT (not the
Abbott Troponin I, which is what was studied in the above Lancet study). [Here is the full text of this randomized
trial: A Randomized Trial of
a 1-Hour Troponin T Protocol in Suspected Acute Coronary Syndromes.]
Spiegel’s
piece starts by conceding that “hs assays....will soon replace the 4th
generation assays currently being used.”
This
hs-cTnT study randomized potential ACS workups to a 0/1 hour hs-cTnT protocol
vs. standard care. In the standard care
arm, 0/3 hour troponins were used and the providers were blinded to any value less
than 29 ng/L (the rationale for hs-cTn is to be able to precisely measure such
small quantities, so this study was testing the value of knowing, vs. not knowing, the precise value of all such
low troponin measurements). The study showed that more patients are
discharged (45.1% vs. 32.3%), and discharged earlier (4.6 vs. 5.6 hrs), with
hs-cTnT 0/1 hour protocol.
Somehow, Dr. Spiegel, in his zeal to
bust “myths,” manages to dismiss these findings!!
As
expected with hs-cTn, the overall number diagnosed with MI was not different
because that is not the function of hs-cTn — it is to diagnose or rule out
acute MI earlier. Moreover, the protocol ruled out MI in 72.1%
with an NPV of 99.6%; in other words, 27% of patients were not discharged even
though the protocol would safely allow for it. No doubt the rate of early
discharge would have been higher if providers had felt comfortable enough with
the new protocol to consistently follow it, a common problem when introducing a
new pathway.
By
30 days, among all 3288 patients, the hs-cTnT group (n=1646), compared to the
standard group (n=1642), had less functional testing (11.0% vs. 7.5%), but the
same number of angiograms, CT coronary angiograms, coronary interventions and
revascularizations. However, among the
1493 with an initial cTnT less than 29 ng/L, there were slightly more
revascularizations in the group using hs-cTnT [38/1515 (2.2%) vs.15/1493 (0.9%)], partly because there were more
index acute MI diagnosed (1.1% vs. 0.5%).
The
number of acute MI, unstable angina, and revascularizations following the index
hospitalization were the same in both groups.
Thus, it would seem that the use of hs-cTnT diagnosed a few more
patients at the index visit, without leading to any decrease in adverse 30-day
outcomes after the visit. The rate of “non-MI myocardial injury”
diagnosis was also slightly higher in the hs-cTnT group (1.6% vs. 1.0%); given than acute myocardial
injury is associated with high mortality, detecting it is not necessarily a bad
thing.
From
the article: “The major downside of noninvasive testing are the downstream
invasive testing and interventions it leads to, both of which were higher in
the rapid diagnostic strategy group.” But the difference is only 1.3%, or only
23 more over 3.5 years!!
Dr.
Spiegel criticizes this tiny bit of higher rate of revascularization: “What
have we really accomplished if hs-cTnT leads to a decrease in noninvasive
testing but increases the number of diagnostic catheterization and
revascularization procedures?”
It
seems obvious to us that what we have accomplished is the diagnosis and treatment of a few more
acute MI, and possibly also the diagnosis of unstable angina that would
need revascularization. Apparently, the
interventionalists caring for these patients thought that their patients’
angiographic coronary disease would benefit from revascularization, probably
because they opined that it was indicative of ACS. It is also possible that some patients of
the patients had stable coronary lesions, which often do not need
revascularization.
But
Dr. Spiegel seems to be implying that the revascularization undertaken
according to the judgment of those patients’ interventionalists was
unnecessary; why would he imply that?
Similar
to his criticism of the earlier article, this criticism also depends on the
notion that one need not treat all acute MI nor all unstable angina, nor even
diagnose them.
It is very likely that these patients had
their lives saved by this procedure.
Spiegel’s
criticism apparently assumes that because there was an absence of difference in
death or acute MI at 30-days, that those interventions were unnecessary. But studies of invasive vs. conservative
management of ACS, most of which show benefit, show that benefit at 1 year, not
at 30 days[1] .
A 30-day outcome is used for this trial to show that it is safe to
discharge the patient if he/she can get follow up within 30 days. If coronary disease is discovered and treated
in the interim, that is not an
adverse outcome.
The
fact that there were more revascularizations is a benefit of hs-cTn, not a complication. It implies that hs-cTnT helped to find
signficant coronary disease. If
interventionalists saw ruptured plaque on angiogram, and this was the reason
for the revascularization, then it is clear that the hs-cTnT was
beneficial. They may well have found
other coronary disease that was NOT revascularized, as it was 1) not thought to
be ACS or the etiology of the symptoms, or 2) was thought to be ACS but not
thought to require revascularization.
Certainly not all presumed ACS with coronary disease requires
revascularization (see the ICTUS trial).
But whether there is coronary intervention or not, there are other
interventions for coronary disease that are very effective, mostly
statins. In fact, we know from a large
CT coronary angiogram study that diagnosing non-ACS
coronary disease does benefit the patient because more preventive therapies are
adhered to.
In
other words, one need not do a coronary intervention in order for it to be
worthwhile to make the diagnosis of acute MI or of coronary disease.
In
summary, more information is better if the provider knows what to do with
it. As we all get more experience with
hs-cTn, and there are more clinical trials and observational studies to guide
us, the more precise information provided by high-sensitivity troponin will be
beneficial to patients and to patient flow.
Myth Busting
Myth-busting is popular and fun, but it is
rarely good science. It's fine and good to approach any field of knowledge or
any dogma with skepticism. And it is great to really overturn untrue dogma. But to turn skepticism into myth-busting, it
is essential to comprehensively
review the existing literature. If you set out intent to bust a myth, then you
can easily find one or two counterexamples to a prevailing heuristic and write
a "Gotcha!" piece on the topic. However, if those who advertise
themselves as myth busters are not primary researchers in the area they are myth-busting,
there is a risk that they will not fully understand the topic and write a
misleading review based on cherry-picked studies that amounts to fake news.
Many venues will be eager to publish these pieces since it will attract
attention both by those interested in learning something new and by those
seeking to correct the inaccurate portrayal of the literature. However, our
medical publications should seek to disseminate reliable information and better
vet pieces that proclaim propositions that run counter to the vast majority of
existing evidence.
Good myth busting in EM:
Here
are very nice examples of well substantiated myth-busting by Salim Rezaie at
Rebel EM: https://rebelem.com/tag/mythbuster/.
CREDIT to Drs. Smith, Limkakeng & Peacock — for their amazingly detailed discussion of the literature regarding use of the HS (high-sensitivity) Troponin assay (and their impressive rebuttal of Emergency Medicine News articles and replies by Dr. Rory Spiegel). The discussion by Drs. Smith, Limkakeng & Peacock is in itself, a lesson in accurate assessment of relevant literature. To summarize my understanding of KEY points (which is to restate the last paragraph of Dr. Smith’s Letter to the Editor of EM News): — “The value of the hs troponin assay — is that it helps in EARLY diagnosis of MI and EARLY rule out. The contemporary (not high-sensitivity) assay ( = cTnI) is excellent, and just as sensitive as hs assays at 6-12 hours after symptom onset.” So, the KEY is to focus on “EARLY”. Our thanks again to Drs. Smith, Limkakeng & Peacock.
ReplyDeleteKudos to Drs. Smith, Limkakeng & Peacock for providing an educational response regarding the power of high sensitivity cardiac troponin assays in clinical practice in response to another individual's misinterpretation of the evidence-based literature.
ReplyDeleteFred Apple PhD, Hennepin Healthcare/Hennepin County Medical Center and the UnIversity of Minnesota
Thanks, Fred!
Delete